1. Home /
  2. Home improvement /
  3. Integrity Fire And Control Systems Inc.


Category

General Information

Locality: Waterdown

Phone: +1 905-690-0805



Address: 329 3rd Con. Rd. E. L0R 2H1 Waterdown, ON, Canada

Website: www.integrityfire.ca

Likes: 46

Reviews

Add review



Facebook Blog

Integrity Fire And Control Systems Inc. 26.10.2020

We are looking for a new member of our team. Please see the comment section of this post for details.

Integrity Fire And Control Systems Inc. 13.10.2020

Wishing you all the best for 2017

Integrity Fire And Control Systems Inc. 27.09.2020

So today's electrical lesson is on extension boxes and what they are used for, and an example of what they are not used for. This is called an 1110 extension ring,it is used to build onto an existing 1110 device box so you can increase wire fill etc. What extension rings can not be used for is the base box as there is no back and no where to put the bonding conductor. This I think was done by an electrician, which is frustrating. Fire alarm wiring is generally is low voltage however it must be installed to the same code requirements as say you would 110 volt circuit.

Integrity Fire And Control Systems Inc. 10.09.2020

I would say this has to be one of the dirtiest smoke detectors I have ever come across, and I have seen a few. All that dust in there looks a lot like smoke inside the sensing chamber, which creates false alarms. It's important to have the fire alarm system checked annually, part of that check is to see if the detectors are getting dirty.

Integrity Fire And Control Systems Inc. 22.08.2020

Well I guess I'm up to date with my Onedrive.

Integrity Fire And Control Systems Inc. 10.08.2020

How many people can tell me what is the electrical defect here.

Integrity Fire And Control Systems Inc. 03.08.2020

This is a public service announcement. At the risk of sounding judgemental here I'm going to say maybe you shouldn't be touching electrical if you don't know the difference between a black and a white wire, or know what the green one is used for. I just saw that in this one install, it sure creates more headaches for the next person who comes along.

Integrity Fire And Control Systems Inc. 31.07.2020

Meet the newest member of the Integrity Fire family. Joshua Scott Jackson was born July 29. He is perfectly healthy and doing great. He is already helping keep mommy company with the office work.

Integrity Fire And Control Systems Inc. 16.07.2020

Welcome to our new facebook page, please check out our website at www.integrityfire.ca