Seebacher Plumbing & Heating Ltd
901 3rd St W # 314 v7p3p9 North Vancouver, BC, Canada
Category
General Information
Locality: North Vancouver, British Columbia
Phone: +1 604-986-0669
Address: 901 3rd St W # 314 v7p3p9 North Vancouver, BC, Canada
Website: seebacher.ca/
Likes: 19
Reviews
Facebook Blog
Replaced a mid efficient furnace and hot water tank with a condensing water heater and air handler.
Removed an atmospheric boiler. Moved all gas and water lines to wall. Magnetic filter inline next to boiler already pulled out big chunks of iron in one day! The new Navien boiler can run 3 different zones without the need for an external zone control module. This was fun!
Installed Combi boiler. It will provide unlimited instant on demand hot water. The boiler board in the center is a zone pump controlled system that sends heated water to an air handler which is replacing a forced air furnace. It will also send heated water to a pool heat exchanger to heat the swimming pool. Below the air handler on the left is an evaporator coil ready for an air conditioning install in spring! Works great!
Just a 5 head ductless split heat pump I installed. These are great for cooling in summer and heating in winter!
Replaced heating system in concrete garage. Used a liner down existing venting from roof. All we needed to do was change the cap outside. Perfect for stratas as no visible changes to exterior of units.
Replaced a 40 gal hot water tank and a very large cast iron furnace with a Navien combi boiler and a Viessman air handler. Boiler injects heat into primary loop. The piping had to fit within a 12 inch space and still be serviceable. A second in floor radiant loop previously put in an addition to the house had to be connected with a mixing valve. My service and heating skills shined in this tight build! All metal work is done by me, on site. My 7 years as a sheet metal fabricator always pay off on these jobs.
Replaced a 40 gal hot water tank and a very large cast iron furnace with a Navien combi boiler and a Viessman air handler. Boiler injects heat into primary loop. The piping had to fit within a 12 inch space and still be serviceable. A second in floor radiant loop previously put in an addition to the house had to be connected with a mixing valve. My service and heating skills shined in this tight build! All metal work is done by me, on site. My 7 years as a sheet metal fabricator always pay off on these jobs.
Replaced a 60 gal hot water tank and a Super Hot boiler with a high efficient condensing Navien combi boiler.
Navien water heater instal.
Condensing boiler heating at 120F. Notice how much condensate is being produced and sent to the neutralizer.
Upgraded home to condensing heating system. Built boiler board and installed Tekmar control system.
Just passed inspection on another furnace and hot water tank retro fit.
Popular Listings
Precision Garage Doors Okanagan
+1 250-800-9328
Businesses, Local service, Home improvement, Garage door service
Taylor Excavation Incorporated
116 Haldimand Road 17 N1A 2W4 Dunnville, ON, Canada
+1 905-515-9779
Home improvement, Forestry service, Agricultural service, Demolition & excavation company
Pemberton Backhoe Service
+1 604-932-8855
Businesses, Local service, Home improvement, Product/service, Demolition & excavation company